Ambulatory Cardiac Devices Objective: Ambulatory cardiac monitors generate findings days after the patient leaves the clinic, arriving as vendor-specific PDFs, CSVs, and proprietary APIs that never reach the ordering cardiologist cleanly. The result is unreviewed arrhythmia episodes, orphaned reports that cannot be matched to an Epic order, and no audit trail for actionable events like sustained AF or pauses. Done looks like: every completed study is matched to its originating order, structured measurements and episode findings land as discrete data, the full disclosure tracing is attached as a viewable document, and the report routes to the correct cardiologist In Basket with significant events flagged. This accelerator packages the Ambulatory Cardiac Devices Epic Data Sharing Playbook as a MuleSoft-anchored solution plan. What's Getting Built Vendor Adapter (System API) — speaks each monitoring vendor's native protocol and emits a canonical study model with both the structured payload and the tracing artifact · POST /webhook/study-complete, GET /studies, SFTP GET /reports Normalize & Match (Process API) — normalizes to a LOINC-keyed model, resolves the Epic order by device serial or enrollment ID, and routes ambiguous studies to human review · POST /studies, GET /ServiceRequest?serial={serial}, POST /review-queue Epic Results (Experience API) — transforms the canonical model to ORU R01 and MDM T02 or DocumentReference and delivers to Epic through Bridges · POST /results/oru, POST /documents/mdm Unmatched Study Store (Object Store) — dead-letters unmatched, malformed, or missing-tracing studies with correlation ID and raw vendor payload for replay · PUBLISH dlq, REPLAY dlq/{correlationId} Vendor Poll (Scheduler) — polls vendors that lack push webhooks, deduping on vendor study ID and checkpointing the last-processed ID · SCHEDULER poll vendor studies Epic Bridges (target) — receives inbound ORU R01 and MDM T02 into Cupid for cardiology review and MyChart release · MLLP SEND ORU^R01, MLLP SEND MDM^T02 Prerequisites Epic Bridges interface engine configured to accept inbound ORU R01 results and MDM T02 document messages over MLLP or the Epic FHIR R4 endpoints for Observation, DiagnosticReport, and DocumentReference Vendor accounts and API or SFTP credentials for each monitoring provider such as iRhythm, Preventice/BioTelemetry, Philips, and Medtronic CareLink with report-ready webhook or polling access Cupid or cardiology procedure order records that carry a monitor serial number or enrollment ID so completed studies can be reconciled to the originating order An Epic Master File map of ordering providers, monitoring procedure codes, and result component OBX definitions for heart rate, ectopy burden, AF burden, and pause metrics Anypoint Platform environment with CloudHub 2.0 or RTF, Anypoint MQ for queuing and dead-letter handling, and Secrets Manager for vendor credentials Epic client and technical services engagement to define the incoming interface spec and OBX value tables 1. Epic interfaces and standards This accelerator implements the Ambulatory Cardiac Devices Epic Data Sharing Playbook. Register the connecting app on Epic on FHIR and confirm the customer has the relevant Epic modules licensed before building. Cupid for cardiology procedure orders results and study review Bridges for HL7v2 ORU R01 result and MDM T02 document ingestion FHIR R4 Observation, DiagnosticReport, DocumentReference, ServiceRequest Hyperdrive In Basket result routing and cosign MyChart results release LOINC and SCP-ECG for cardiac measurement and rhythm coding Architecture 2. Business requirements Match every completed study to its originating Epic order using the monitor serial or enrollment ID, and quarantine studies that cannot be matched rather than filing them to the wrong patient. File discrete measurements such as heart rate min/mean/max, AF burden, ectopy burden, longest pause, and symptom-diary correlation as OBX components, not as free text buried in a PDF. Attach the full disclosure tracing and episode strips as a viewable DocumentReference so the cardiologist reads the actual ECG, not a summary. Flag clinically significant findings such as sustained AF, pauses over threshold, and VT so they surface at the top of the In Basket instead of blending into routine results. Distinguish study types Holter, event, MCT, and long-term continuous because each has different completion semantics and reporting cadence. 3. Ingestion and vendor normalization Build one System API per vendor that speaks the vendor native protocol such as REST webhook, polling API, or SFTP drop and emits a canonical internal study model. Prefer vendor push webhooks over polling; where only polling exists, poll on a schedule and dedupe on vendor study ID to avoid re-filing the same report. Map vendor measurement fields to a canonical DataWeave model keyed to LOINC codes so downstream mapping is vendor-agnostic. Pull both the structured result payload and the tracing PDF or SCP-ECG artifact in the same transaction, and fail the study if either is missing. Stamp a correlation ID at ingestion that follows the study through matching, mapping, and Epic acknowledgment. 4. Order matching and patient identity Resolve the Epic patient and ServiceRequest by querying with the monitor serial or enrollment ID captured at hookup, not by fuzzy name and DOB matching. When the enrollment ID is missing, fall back to a demographic match against the order and route ambiguous results to a human review queue rather than auto-filing. Verify the resolved order is still active and for a cardiac monitoring procedure before filing, to catch reused devices assigned to a new patient. Carry the resolved ordering provider onto the result so In Basket routing and cosign land on the right cardiologist. Reject and alert on studies whose device serial maps to more than one open order, which signals a device-reassignment data error. 5. Mapping and delivery to Epic Transform the canonical model to an ORU R01 for discrete results and an MDM T02 or FHIR DocumentReference for the tracing, linking both to the same placer and filler order number. Populate OBX segments with LOINC-coded components and set abnormal flags in OBX-8 for out-of-range measurements so Epic best-practice logic can fire. Set result priority and the significant-event flag so sustained AF, high-grade pauses, and VT route as high-priority In Basket items. Send an ORU with a preliminary or final status that mirrors the vendor report state, and never overwrite a final with a stale preliminary. Hold MyChart release until the cardiologist verifies, so patients do not see unreviewed arrhythmia findings. 6. Error handling and operations Route unmatched, malformed, or missing-tracing studies to a dead-letter queue with the correlation ID and the raw vendor payload attached for replay. Alert on the absence of an expected report for an active study past its expected completion window, which is the failure mode dashboards miss most often. Persist the last-processed vendor study ID per vendor so a connector restart does not replay or skip reports. Reconcile Epic application acknowledgments AA versus AE and AR against sent messages and retry AE and AR with backoff before dead-lettering. Track per-vendor latency from study completion to In Basket arrival, since a slow vendor feed is a patient-safety issue, not just a metric. 7. Security and compliance Encrypt PHI in transit and at rest. Audit-log every access to and modification of patient data, and carry a correlation ID end to end. Enforce minimum-necessary access for integration operators and support users. Encrypt vendor credentials in Anypoint Secrets Manager and rotate per-vendor API keys and SFTP keys on a fixed schedule and never inline them in connector config Validate that each inbound study device serial belongs to an active enrollment before dereferencing PHI to prevent cross-patient leakage from reassigned devices Store tracing PDFs and SCP-ECG artifacts only transiently in the integration tier then hand them to Epic and purge keeping the mule tier free of a standing ECG data store Mutually authenticate vendor webhook callers with mTLS or signed payloads so a spoofed webhook cannot inject a fabricated cardiac result Sample payload — ORU R01 for a completed 14-day MCT study with AF burden MSH|^~\&|MCT_VENDOR|CARDIONET|EPIC|HOSP|20260819143000||ORU^R01|MSG00042|P|2.5.1 PID|1||E1000234^^^EPIC^MR||DOE^JANE^A||19550312|F ORC|RE|MON778812^EPIC|STDY-2026-55110^CARDIONET||CM OBR|1|MON778812^EPIC|STDY-2026-55110^CARDIONET|93229^Ambulatory MCT 14 day^CPT|||20260805090000|20260819090000 OBX|1|NM|8867-4^Heart rate mean^LN||72|/min|60-100|N|||F OBX|2|NM|76629-5^AF burden percent^LN||8.4|%|0-0|A|||F OBX|3|NM|8873-4^Longest RR pause^LN||3.2|s|0-2|A|||F OBX|4|ST|18844-1^Rhythm interpretation^LN||Paroxysmal atrial fibrillation longest episode 6h 12m||||A|||F OBX|5|RP|59284-0^Full disclosure tracing^LN||STDY-2026-55110.pdf^application/pdf||||||F Testing and validation Feed a synthetic completed study through each vendor System API and assert the canonical model captures every LOINC-mapped measurement and both the structured payload and tracing artifact Test order matching with a valid enrollment ID a missing ID and a serial mapped to two open orders and confirm ambiguous cases route to human review and to an alert Validate the generated ORU R01 against the Epic interface spec including OBX abnormal flags and the preliminary-to-final status transition Confirm a preliminary result does not overwrite a previously filed final for the same study ID and that AE or AR acknowledgments retry with backoff before dead-lettering Verify a significant-event study such as sustained AF pause over threshold or VT sets high priority and routes to the ordering cardiologist In Basket Phased rollout Phase 1 — Connect Stand up one vendor System API against a sandbox account and confirm webhook or polling delivery of completed studies with tracings. Establish the Epic Bridges inbound interface and exchange test ORU R01 and MDM T02 messages end to end. Phase 2 — Map and test Build the canonical model and DataWeave maps to LOINC-coded OBX components, and validate against the Epic interface spec. Wire order matching by device serial and enrollment ID, with the human-review and alert paths for unmatched and ambiguous studies. Phase 3 — Production Go live with a single high-volume vendor and monitor per-vendor completion-to-In-Basket latency and unmatched rates. Onboard remaining vendors behind the same canonical model and enable MyChart release after cardiologist verification. Success metrics Percent of completed studies auto-matched to an Epic order without human review Median and p95 latency from vendor study completion to cardiology In Basket arrival Count of studies dead-lettered per vendor per week by cause such as unmatched malformed or missing tracing Percent of significant-event studies flagged high priority and acknowledged within the target window Troubleshooting Completed studies arrive but land in the review queue instead of auto-filing. — Likely cause: The monitor serial or enrollment ID captured at hookup was not written to the Epic ServiceRequest, so identity resolution falls back to demographic matching. Fix: Confirm the enrollment ID flows onto the order at device dispensing and reconcile the vendor device-registration feed against open orders. Cardiologists see a summary but cannot open the full ECG tracing. — Likely cause: The MDM T02 or DocumentReference was sent without the tracing artifact, or the artifact fetch failed while the structured result still went through. Fix: Enforce the both-or-neither rule at ingestion so a study fails when either the structured payload or the tracing is missing, and replay from the DLQ once the artifact is available. A final report shows stale preliminary measurements in Cupid. — Likely cause: A late-arriving preliminary ORU overwrote the final because status ordering was not enforced. Fix: Track result status per vendor study ID and drop any preliminary that arrives after a final has been filed. The same study is filed to Epic twice. — Likely cause: A polling connector re-fetched a report after a restart without checkpointing the last-processed vendor study ID. Fix: Persist the last-processed study ID per vendor and dedupe on it before mapping and delivery. Deliverable: A deployable Anypoint blueprint that ingests Holter, event, MCT, and long-term continuous cardiac monitor reports from vendor portals, normalizes them to FHIR R4 Observation and DiagnosticReport plus an ORU R01, and files episode summaries and PDF tracings to Epic Cupid and the patient chart for cardiology review and MyChart release.