Meet the MQSA communication rules without a tracking spreadsheet — structured mammography assessments normalized from the RIS, a clock per exam for the 7-day and 30-day deadlines and incomplete-exam finalization, lay summaries and provider reports with the federal density statement inserted verbatim, follow-ups that close only on a linked result, documented decline, or confirmed care elsewhere, and pathology correlation feeding the annual medical outcomes audit.
Tags: healthcare, provider, radiology, mammography, mqsa, breast-density, results-management, follow-up-tracking, patient-communication, pathology, api-led, process-api, hl7v2, epic, fhir
Breast Imaging Results: MQSA Notification Clocks, Density Letters, and Follow-Up Tracking
Review the regulatory requirements before implementing. The regulatory details in this blueprint are general guidance, not legal or compliance advice — rules change, and state density notification laws vary. Before you build, have the lead interpreting physician and the MQSA compliance owner confirm these against the current MQSA regulations (21 CFR Part 900):
- Step 2: 7 days for Suspicious and Highly Suggestive of Malignancy, 30 days for all other categories, 30-day finalization for Incomplete — need prior mammograms, and direct reports to self-referred patients.
- Step 1: the assessment category list and the mapping from the four density categories to the dense and not-dense statements.
- Step 3: federal density statements used verbatim, with state-required wording kept separate.
- Steps 5 and 6: medical outcomes audit contents and the record retention period.
Deliverable: A breast imaging results Process API that reads structured mammography reports from the RIS, starts the MQSA communication clock for each exam, sends provider reports and patient lay summaries with the federally prescribed density statement, tracks every recommended follow-up until a result closes it, and feeds pathology correlation into the annual medical outcomes audit.
Objective: Since September 2024, MQSA requires every mammography facility to send a lay summary with a breast density statement, to communicate Suspicious and Highly Suggestive of Malignancy results within 7 days, and to finalize exams marked incomplete for want of prior films within 30 days. Most breast centers meet those rules with a mix of reporting-system letters, a tracking spreadsheet, and a navigator's memory. The failures are quiet: a six-month follow-up nobody scheduled, a biopsy recommendation lost when the patient changed providers, a density letter that paraphrased the federal wording. Working looks like a clock per exam that nobody has to remember, letters generated from the structured assessment with the required language intact, and a follow-up that stays open until a result — not a phone call — closes it.
What's Getting Built
- Mammography results (System API) — receives final and addended reports from the RIS or mammography reporting system with structured assessment and density ·
POST /imaging-results (HL7v2 ORU), GET /exams/{accession}
- Assessment normalizer (Process API) — maps reporting-system codes to the MQSA assessment categories and density categories ·
POST /assessments/normalize
- Communication clocks (Process API) — computes due dates for the provider report, lay summary, and incomplete-exam finalization, and alerts before they lapse ·
GET /clocks?due=, PATCH /clocks/{id}
- Letters (Process API) — builds provider reports and lay summaries from templates, with the density statement inserted verbatim, and hands them to print, mail, or the portal ·
POST /letters, GET /letters/{id}/status
- Follow-up tracker (Process API) — opens a follow-up for every recommendation and closes it only on a linked result, a documented decline, or confirmed care elsewhere ·
POST /followups, GET /followups?status=open&overdue=true, PATCH /followups/{id}
- Pathology correlation (System API) — links biopsy pathology to the imaging recommendation that prompted it ·
GET /pathology?patient=&since=
- Outcomes audit (Experience API) — recall rate, positive predictive values, and cancer detection rate per facility and interpreting physician ·
GET /audit/outcomes?year=
Prerequisites
- Anypoint Platform org and an HL7v2 ORU feed from
{ris} or {mammo_reporting_system} that carries the assessment and density as coded fields, not only in narrative text.
- The facility's MQSA lay summary and report templates, with the federal density statements approved by the lead interpreting physician; any
{state_density_notice} wording approved separately.
- A letter channel — portal, print-and-mail vendor, or both. Payer Correspondence and Document Management covers print, mail, and delivery tracking.
- Scheduling access for follow-up exams through Appointment Scheduling, and a pathology result feed — see Digital Pathology where pathology runs in the EHR.
- Named owners: the lead interpreting physician for MQSA compliance and the breast navigator team for follow-up work.
Choose your path
- EHR mammography module — Choose when the EHR's breast imaging application already reports and tracks. The integration adds the clocks, the letter channel, the outcomes audit, and outreach the module doesn't do.
- Standalone tracking — Choose when mammography reports come from a separate RIS or reporting system. The follow-up tracker here is the system of record, and the EHR receives results and follow-up status.
Both paths share the assessment normalizer and the clock rules — the MQSA logic is written once.
Architecture
1. Structured assessment, not narrative
- Read the assessment and density from coded ORU fields and map them to the MQSA categories: Negative, Benign, Probably Benign, Suspicious, Highly Suggestive of Malignancy, Known Biopsy-Proven Malignancy, Post-Procedure Mammogram for Marker Placement, and the two Incomplete categories — need additional imaging and need prior mammograms.
- Map density to the four categories and then to dense (heterogeneously or extremely dense) or not dense (almost entirely fatty or scattered fibroglandular), which decides the statement.
- Reject a report without a coded assessment to a worklist. Never infer the category from the impression text.
2. Clocks per exam
- Start the clock at the final interpretation. Suspicious and Highly Suggestive of Malignancy: provider report and patient communication within 7 days. All other categories: provider report and lay summary within 30 days.
- Incomplete — need prior mammograms: a follow-up report with a final assessment is due within 30 days of the initial report. Track the request for outside films as part of that clock.
- Self-referred patients with no provider get the report sent to them directly.
- Warn the navigator team
{clock_warning_days} before any clock lapses, and record the delivery evidence that stopped it.
3. Letters with the federal language intact
- Generate lay summaries and provider reports from the structured assessment; plain language, the patient's preferred language, and the density statement for the patient's category inserted verbatim.
- Store the federal statements as approved, versioned text and check each generated letter against them. Add
{state_density_notice} language only as a separate paragraph — never edit the federal statement.
- A report addendum that changes the assessment recomputes the clock and sends a corrected letter.
4. Follow-up until a result closes it
- Open a follow-up for every recommendation: additional imaging for Incomplete, short-interval imaging for Probably Benign, tissue diagnosis for Suspicious and Highly Suggestive.
- Close a follow-up only on a linked result (the next exam or a pathology report), a documented patient decline, or confirmed care elsewhere with the receiving facility named.
- Schedule directly where possible, then escalate in steps — portal, call, letter — up to
{outreach_attempts} before the navigator decides next steps.
5. Pathology correlation and outcomes audit
- Link biopsy pathology to the recommendation and exam that led to it, including biopsies performed outside the facility when the report comes back.
- Produce the annual MQSA medical outcomes audit: positive exams, biopsy results, and cancers detected, with recall rate, positive predictive values, and cancer detection rate per interpreting physician.
6. Security and compliance
- Encrypt PHI in transit and at rest; letters in the print queue are encrypted and purged after delivery confirmation.
- Retain clocks, letters, and delivery evidence for the MQSA retention period — they are what an inspector asks for.
- Restrict per-physician audit views to the lead interpreting physician and quality staff.
- Complete the shared Healthcare integration configuration checklist.
Configure with your own values: {ris}, {mammo_reporting_system}, {state_density_notice}, {clock_warning_days}, {outreach_attempts}.
Sample payload — suspicious exam with open follow-up
{
"accession": "MG-2026-0418-0771",
"patient": { "mrn": "E4410093", "preferredLanguage": "en", "selfReferred": false },
"interpretedAt": "2026-04-18T16:22:05Z",
"assessment": { "source": "BI-RADS 4", "mqsaCategory": "SUSPICIOUS" },
"density": { "category": "HETEROGENEOUSLY_DENSE", "statement": "DENSE", "statementVersion": "FED-2024.1" },
"clocks": [
{ "type": "PROVIDER_REPORT", "dueBy": "2026-04-25", "status": "MET", "evidence": "letter/L-99120" },
{ "type": "PATIENT_COMMUNICATION", "dueBy": "2026-04-25", "status": "MET", "evidence": "portal/read-2026-04-19" }
],
"followup": {
"id": "FU-31882",
"recommendation": "TISSUE_DIAGNOSIS",
"status": "OPEN",
"scheduled": "2026-04-23",
"closesOn": ["LINKED_PATHOLOGY", "DOCUMENTED_DECLINE", "CARE_ELSEWHERE_CONFIRMED"]
}
}
Deterministic checks
- Clock due dates are a pure function of assessment category and interpretation time; the same report always yields the same dates.
- Every generated lay summary contains the approved density statement for the patient's category, byte for byte; a mismatch blocks the letter.
PATCH /followups/{id} to closed without a linked result, a documented decline, or a named receiving facility returns 422.
- Result ingestion is idempotent on accession number plus report version; an addendum updates the exam, never duplicates it.
- A report without a coded assessment never starts a clock or a letter; it goes to the worklist.
- MUnit suites cover every assessment category, both density outcomes, addenda that change the category, and self-referred patients.
Testing and validation
- Replay a quarter of historical reports and compare computed clocks with what was actually sent and when.
- Send an Incomplete — need prior mammograms exam, then a final report on day 29 and another on day 31; confirm the clock records met and missed.
- Generate lay summaries for every density category in each supported language and have the lead interpreting physician sign them off.
- Close a follow-up with an outside pathology report and confirm it appears in the outcomes audit.
Phased rollout
Phase 1 — Connect
- Ingest reports, normalize assessments, and compute clocks in shadow mode alongside the current process.
Phase 2 — Map and validate
- Generate letters and open follow-ups; navigators work the new worklist in parallel with the spreadsheet for a month.
Phase 3 — Production
- Retire the spreadsheet, turn on outreach escalation, and produce the first outcomes audit from the pipeline.
Success metrics
- Communication clocks met on time, per category — the 7-day clock is the one to watch.
- Follow-ups overdue past
{clock_warning_days}, and median days from recommendation to biopsy.
- Follow-ups closed by result versus decline versus lost — lost should trend to zero.
- Hours to assemble the annual outcomes audit.
- Platform: report-to-letter latency and letter delivery failure rate.
Troubleshooting
- Clocks missing for some exams — Likely cause: assessments only in narrative text. Fix: require coded assessment fields from the reporting system and route exceptions to the worklist.
- An inspector flags a density letter — Likely cause: template edited locally. Fix: version the federal statements, check every letter against them, and keep state wording separate.
- Follow-ups closed without a result — Likely cause: closed on a scheduled appointment instead of a completed exam. Fix: close only on a linked result, decline, or confirmed care elsewhere.
- PPV looks wrong in the audit — Likely cause: outside pathology never linked. Fix: request results for every biopsy recommendation and link them when they arrive.